net - Networks

This feature is related to the network and provides interfaces of configuring and querying the information of the network mode, such as getting the network registration status and setting the network searching mode.

Note: It is recommended that you should configure the APN information of the corresponding operator when using SIM cards of different operators. If the APN information is not configured or the configuration is incorrect, the module may not register on the network. See dataCall.setPDPContext for methods of how to configure the APN information.

Get Signal Strength

net.csqQueryPoll

net.csqQueryPoll()

This method gets the signal strength.

Return Value:

Value of CSQ signal strength - Successful execution

-1 - Failed execution

99 - Error

Note: Range of the value of signal strength: 0–31. The higher the value, the better the signal strength.

Example:

>>> import net
>>> net.csqQueryPoll()
31

Get Cell Information

net.getCellInfo

net.getCellInfo()

This method gets the information of neighbour cells.

Return Value:

List of the information of three network modes (GSM, UMTS, LTE) - Successful execution.

-1 - Failed execution.

An empty list - The information of the corresponding network mode is empty.

([(flag, cid, mcc, mnc, lac, arfcn, bsic, rssi)], [(flag, cid, licd, mcc, mnc, lac, uarfcn, psc, rssi)], [(flag, cid, mcc, mnc, pci, tac, earfcn, rssi, rsrq, sinr),...])

  • Descriptions of GSM network mode
Parameter Description
flag Cell type. Range: 0–3. 0: Current serving cell. 1: Neighbour cell. 2: Intra-frequency neighbour cell. 3: Inter-frequency neighbour cell.
cid Cell ID in GSM network. 0 indicates empty. Range: 0–65535.
mcc Mobile Country Code. Range: 0–999.
Note: For EC600N/EC600E/EC800E/EC200A/EC600M/EC800M/BG95 series module, the value needs to be converted to hexadecimal. For example, Decimal number 1120 is 0x460 in hexadecimal in which 460 indicates MCC460. For other series modules, this value is in decimal format.
mnc Mobile Network Code. Range: 0–99.
Note: For EC600N/EC600E/EC800E/EC200A/EC600M/EC800M/BG95 series module, the value needs to be converted to hexadecimal.
lac Location Area Code. Range: 1–65535.
arfcn Absolute Radio Frequency Channel Number. Range: 0–65535.
bsic Base Station Identification Code. Range: 0–63.
rssi In GSM network, this value indicates Rx level and describes the received signal strength. 99 indicates unknown or undetectable.
RSSI = RXLEV - 111. Unit: dBm. Range of RXLEV: 0–63. Range of RSSI: -111 to -48 dBm.
  • Descriptions of UMTS network mode
Parameter Description
flag Cell type. Range: 0–3. 0: Current serving cell. 1: Neighbour cell. 2: Intra-frequency neighbour cell. 3: Inter-frequency neighbour cell.
cid Cell identity in UMTS network mode. Cell identity = RNC_ID × 65536 + Cell_ID. Range of cell identity: 0x0000000–0xFFFFFFF (The cell identity is 28 bits). It means that the first two bytes of cell identity indicate RNC_ID and the last two bytes indicate Cell_ ID. Range of Cell_ID: 0–65535.
lcid URA ID. Range: 0–65535. 0 indicates that the information does not exist.
mcc Mobile Country Code. Range: 0–999.
mnc Mobile Network Code. Range: 0–99.
lac Location Area Code. Range: 1–65535.
uarfcn UTRA Absolute Radio Frequency Channel Number. Range: 0–65535.
psc Primary Scrambling Code. This parameter determines the primary scrambling code of the scanned cell. Range: 0–511.
rssi In UMTS network, this value indicates received signal code power (RSCP), that is CPICH/PCCPCH.
RSSI = RSCP - 115. Unit: dBm. Range: -121 to -25 dBm.
  • Descriptions of LTE network mode
Parameter Description
flag Cell type. Range: 0–3. 0: Current serving cell. 1: Neighbour cell. 2: Intra-frequency neighbour cell. 3: Inter-frequency neighbour cell.
cid Cell identity, also called E-UTRAN cell identifier (ECI) in LTE network. ECI = eNodeB ID × 256 + Cell ID. Range: 0x0000000–0xFFFFFFF (The cell identity is 28 bits). The first 20 bits indicate eNodeB ID. The last 8 bits indicate LTE Cell ID.
mcc Mobile Country Code. Range: 0–999.
mnc Mobile Network Code. Range: 0–99.
pci Physical-layer cell identity. Range: 0–503.
tac Tracking Area Code. Range: 0–65535.
earfcn E-UTRA Absolute Radio Frequency Channel Number. Range: 0–65535.
rssi In LTE network, RSSI indicates all received signal strength. Range: -140 to -44. Unit: dBm.
Note: All series modules cannot get RSSI currently but use RSRP, excluding BC25/BG95 series module.
RSRP indicates received effective signal strength. Range: -140 to -44. Unit: dBm.
rsrq Reference signal receiving quality (RSRQ) of the LTE network. Range: -20 to -3.
Note: Theoretically, RSRQ ranges from -19.5 to -3. But due to the problem of calculation method, the supported RSRQ ranges from -20 to -3.
Currently, it is meaningful to get this parameter only for BC25/BG95/EC600E/EC800E series module. This parameter is meaningless for other modules.

Note: This interface will block for 3–5 seconds when searching for cells. In areas without signals, the blocking time will be longer.

BC32 series modules support only NB networks.

Example:

>>> import net
>>> net.getCellInfo()
([], [], [(0, 232301375, 1120, 17, 378, 26909, 1850, -66, -8), (3, 110110494, 1120, 17, 10, 26909, 2452, -87, -17), (3, 94542859, 1120, 1, 465, 56848, 1650, -75, -10), 
(3, 94472037, 1120, 1, 369, 56848, 3745, -84, -20)])

>>> net.getCellInfo()
([], [], [(0, 17104243, 460, 4, 121, 19472, 3688, -76, -15)])

Network Mode and Roaming Configuration

net.getConfig

net.getConfig()

This method gets the current network mode and roaming configuration.

Return Value:

-1 - Failed execution

A tuple containing the current preferred network mode and roaming enabling status - Successful execution

  • Network mode
Value Network mode Value Network mode
0 GSM 17 UMTS_LTE (Dual-link)
1 UMTS 18 GSM_UMTS_LTE (Dual-link)
2 GSM_UMTS (Automatic) 19 CATM supported by BG95 series module.
3 GSM_UMTS (GSM prefer) 20 GSM_CATM (GSM prefer) supported by BG95 series module.
4 GSM_UMTS (UMTS prefer) 21 CATNB supported by BG95 series module.
5 LTE 22 GSM_CATNB (GSM prefer) supported by BG95/BC32 series module.
6 GSM_LTE (Automatic) 23 CATM_CATNB (CATM prefer) supported by BG95 series module.
7 GSM_LTE (GSM prefer) 24 GSM_CATM_CATNB (GSM prefer) supported by BG95 series module.
8 GSM_LTE (LTE prefer) 25 CATM_GSM (CATM prefer) supported by BG95 series module.
9 UMTS_LTE (Automatic) 26 CATNB_GSM (CATNB prefer) supported by BG95/BC32 series module.
10 UMTS_LTE (UMTS prefer) 27 CATNB_CATM (CATNB prefer) supported by BG95 series module.
11 UMTS_LTE (LTE prefer) 28 GSM_CATNB_CATM (GSM prefer) supported by BG95 series module.
12 GSM_UMTS_LTE (Automatic) 29 CATM_GSM_CATNB (CATM prefer) supported by BG95 series module.
13 GSM_UMTS_LTE (GSM prefer) 30 CATM_CATNB_GSM (CATM prefer) supported by BG95 series module.
14 GSM_UMTS_LTE (UMTS prefer) 31 CATNB_GSM_CATM (CATNB prefer) supported by BG95 series module.
15 GSM_UMTS_LTE (LTE prefer) 32 CATNB_CATM_GSM (CATNB prefer) supported by BG95 series module.
16 GSM_LTE (Dual-link) 33 CATNB_GSM (Enterprise) supported by BC32 series module.

BC25 series module does not support this method.

BG95-M1 series module only supports CAT-M network mode.

BG95-M2 series module only supports two network modes: CAT-M and CATNB.

BG95-M3/M8 series module supports three network modes: CAT-M, CATNB and GSM.

BC32 series module configurations related to Enterprise standards need to be restarted to take effect. Changing the network format requires cfun=0.

Example:

>>> import net
>>>net.getConfig ()
(8, False)

net.setConfig

net.setConfig(mode [, roaming])

This method sets the network mode and roaming configuration.

Parameter:

  • mode - Integer type. Network mode. See the above table of network modes for details.

  • roaming - Integer type. Roaming switch. Optional parameter (0: Disable, 1: enable).

Return Value:

0 - Successful execution

-1 - Failed execution

  • roaming is an optional parameter, which can be omitted for unsupported module models.
  • BC25 series module does not support this method.
  • EC200U/EC600U/EG915U/EG912U series module does not support the configuration of roaming parameters and only supports network modes GSM, GSM_LTE (automatic) and GSM_LTE (LTE preferred).
  • EC600E/EC800E/EC800M series module only supports LTE network mode.
  • UC200A series module only supports 2G/3G network mode.
  • EC200A series modules are not saved after power failure.

Example:

>>> import net
>>>net.setConfig(6)
0

>>>net.getConfig ()
(6, False)

Get Network Configuration Mode

net.getNetMode

net.getNetMode()

This method gets the network configuration mode.

Return Value:

-1 - Failed execution

A tuple (selection_mode, mcc, mnc, act) - Successful execution

Parameter Type Description
selection_mode Integer Method. 0 - Automatically. 1 - Manually.
mcc String Mobile Country Code.
mnc String Mobile Network Code.
act Integer ACT mode of the preferred network.

Enumeration values of ACT modes:

Value ACT Mode
0 GSM
1 COMPACT
2 UTRAN
3 GSM wEGPRS
4 UTRAN wHSDPA
5 UTRAN wHSUPA
6 UTRAN wHSDPA HSUPA
7 E UTRAN
8 UTRAN HSPAP
9 E UTRAN CA
10 NONE

Enumeration values of ACT modes of BG95 series module:

Value ACT Mode
0 GSM
1 GSM COMPACT
2 UTRAN
3 GSM wEGPRS
4 UTRAN wHSDPA
5 UTRAN wHSUPA
6 UTRAN wHSDPA HSUPA
7 E_UTRAN
8 UTRAN HSPAP
9 E_UTRAN_CA
10 E_UTRAN_NBIOT
11 E_UTRAN_EMTC
12 NONE

Example:

>>> import net
>>> net.getNetMode()
(0, '460', '46', 7)

Get Detailed Signal Strength

net.getSignal

net.getSignal([sinrEnable])

This method gets the detailed signal strength.

Parameter:

  • sinrEnable - Integer type. Optional parameter. Enable or disable to get SINR.
Value Description
0 Disable to get SINR
1 Enable to get SINR

Return Value:

-1 - Failed execution

A tuple containing (GW, LTE) - Successful execution

([rssi, bitErrorRate, rscp, ecno], [rssi, rsrp, rsrq, cqi, sinr])

  • Descriptions of GSM/WCDMA :
Parameter Description
rssi In GSM and WCDMA network, this value indicates Rx level and describes the received signal strength. 99 indicates unknown or undetectable.
RSSI = RXLEV - 111. Range of RXLEV: 0–63. Unit: dBm.
bitErrorRate Bit error rate. Range: 0–7. 99 indicates unknown or undetectable.
rscp Receive Signal Channel Power. Range: -121 to -25 dBm. 255 indicates unknown or undetectable.
ecno Pilot channel. Range: -24–0. 255 indicates unknown or undetectable.
  • Descriptions of LTE :
Parameter Description
rssi Received Signal Strength Indicator. Range: -140 to -44 dBm. 99 indicates unknown or undetectable.
rsrp Reference Signal Receiving Power. Range: -140 to -44 dBm. 99 indicates unknown or undetectable.
rsrq Reference Signal Receiving Quality. Range: -20 to -3 dBm. The higher the value, the better the reference signal received quality. 255 indicates unknown or undetectable.
cqi Channel Quality Indication. 255 indicates unknown or undetectable.
sinr Signal to interference plus Noise Ratio. Range: -10–40 dBm. 255 indicates unknown or undetectable.
  • sinrEnable is an optional parameter, which can be omitted for the unsupported modules. If you do not enter this parameter, sinr won't be got by default.
  • All Quectel series modules support to get sinr, excluding BC25/BC32 series module.
  • BC32 series modules support only NB networks.

Example:

>>> import net
>>>net.getSignal()
([99, 99, 255, 255], [-51, -76, -5, 255])
>>>net.getSignal(0)
([99, 99, 255, 255], [-51, -76, -5, 255])
>>>net.getSignal(1)
([99, 99, 255, 255], [-51, -76, -5, 255, 18])

Get Current Base Station Time

net.nitzTime

net.nitzTime()

This method gets the current base station time, which is the time issued by the base station when the module boots and registers on the network successfully.

Return Value:

-1 - Failed execution

A tuple (date, abs_time, leap_sec) containing the base station time and corresponding timestamps and leap seconds (0 indicates that the current base station time is unavailable.) - Successful execution

Parameter Type Description
date String Base time. The part of the time zone varies with module models. See the example below for details.
Please use setTimeZone(offset) and getTimeZone() of utime feature if you need to set and get the time zone.
The unit of these two interfaces is hour for different modules. See utime for details.
abs_time Integer Absolute seconds of the base station time.
leap_sec Integer Leap seconds.

Example:

>>> import net
>>> net.nitzTime() 
# For return values of EC100Y/EC200N/EC600N/EC600S/EC800N/EG912N/EG915N/EC600M/EC800M/EG810M/EC200A series module, the unit of the time zone is hour. 8 indicates UTC + 08:00. 
('21/10/26 06:08:03 8 0', 1635228483, 0)  
# For return values of BC25/BC32/EC600E/EC800E/EC200U/EC600U/EG912U/EG915U/EC600G/EC800G series module, the unit of the time zone is 15 minutes. +32 indicates UTC + 08:00.
('20/11/26 02:13:25 +32 0', 1606356805, 0)
# For return values of BG95 series module, there is no time zone.  
('23/02/14 02:25:13', 1676312713, 0)

Get Operator Information

net.operatorName

net.operatorName()

This method gets the operator information of the current network registration.

Return Value:

-1 - Failed execution

A tuple (long_eons, short_eons, mcc, mnc) containing the operator information of the current network registration - Successful execution

Parameter Type Description
long_eons String Operator's full name.
short_eons String Operator's name abbreviation.
mcc String Mobile Country Code
mnc String Mobile Network Code

Example:

>>> import net
>>> net.operatorName()
('CHN-UNICOM', 'UNICOM', '460', '01')

Get Network Registration Information

net.getState

net.getState()

This interface gets the network registration information.

Return Value:

-1 - Failed execution

A tuple ([voice_state, voice_lac, voice_cid, voice_rat, voice_reject_cause, voice_psc], [data_state, data_lac, data_cid, data_rat, data_reject_cause, data_psc]) containing the information of the phone and network registration - Successful execution

voice_state, voice_lac, voice_cid, voice_rat, voice_reject_cause, voice_psc - Information of the phone registration

data_state, data_lac, data_cid, data_rat, data_reject_cause, data_psc - Information of the current network registration

  • Parameter:
Parameter Description
state Network registration status. See the table below for details.
lac Location Area Code. Range: 1–65535.
cid Cell ID. Range: 0x00000000–0x0FFFFFFF. See return values above of net.getCellInfo() for details.
rat Access technology. See the following table for details.
reject_cause Reasons for registration rejection. For EC200U/EC600U/EG915U/BC25 series module, this parameter is necessary and it is not an optional parameter.
psc Primary scrambling code. For EC200U/EC600U/EG915U/BC25 series module, this parameter is necessary and it is not a valid parameter.
  • Enumeration values of state:
Value Description
0 Not registered and MT is not searching for an operator again.
1 Registration completed. Local network.
2 Not registered but MT is searching for an operator.
3 Registration denied.
4 Unknown.
5 Registration completed. Roaming network.
6 Registered on "SMS only" local network (inapplicable).
7 Registered on "SMS only" roaming network (inapplicable).
8 Emergency attachment is limited to emergency bearer service.
9 Registered on "Low priority of CSFB" local network (inapplicable).
10 Registered on "Low priority of CSFB" roaming network (inapplicable).
11 Emergency bearer service only.
  • access technology
Value Description
0 GSM
1 GSM COMPACT
2 UTRAN
3 GSM wEGPRS
4 UTRAN wHSDPA
5 UTRAN wHSUPA
6 UTRAN wHSDPA HSUPA
7 E_UTRAN
8 UTRAN HSPAP
9 E_UTRAN_CA
10 NONE

For BG95 series module:

Value Description
0 GSM
1 GSM COMPACT
2 UTRAN
3 GSM wEGPRS
4 UTRAN wHSDPA
5 UTRAN wHSUPA
6 UTRAN wHSDPA HSUPA
7 E_UTRAN
8 UTRAN HSPAP
9 E_UTRAN_CA
10 E_UTRAN_NBIOT
11 E_UTRAN_EMTC
12 NONE

Example:

>>> import net
>>> net.getState()
([11, 26909, 232301323, 7, 0, 466], [0, 26909, 232301323, 7, 0, 0])

Get Cell ID

net.getCi

net.getCi()

This method gets neighbour cells. The result gotten by this interface is the collection of cell IDs in the result gotten by net.getCellInfo().

Return Value:

An array [id, ……, id] containing cell IDs. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution

-1 - Failed execution

Example:

>>> net.getCi()
[14071232, 0]

net.getServingCi

net.getServingCi()

This method gets the serving cell ID. The result gotten by this interface is the collection of cell IDs in the result gotten by net.getCellInfo().

Return Value:

Serving cell ID - Successful execution

-1 - Failed execution

Example:

>>> import net
>>> net.getServingCi()
94938399

Get MNC of Cell

net.getMnc

net.getMnc()

This method gets MNC of the neighbour cell ID. The result gotten by this interface is the collection of MNCs in the result gotten by net.getCellInfo().

Return Value:

An array [mnc, ……, mnc] containing mnc of cells. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution

-1 - Failed execution

Example:

>>> import net
>>> net.getMnc()
[0, 0]

net.getServingMnc

net.getServingMnc()

This method gets MNC of the serving cell. The result gotten by this interface is the collection of MNCs in the result gotten by net.getCellInfo().

Return Value:

mnc of the serving cell - Successful execution

-1 - Failed execution

Example:

>>> import net
>>> net.getServingMnc()
1

Get MCC of Cell

net.getMcc

net.getMcc()

This method gets MCCs of the neighbour cells. The result gotten by this interface is the collection of MCCs in the result gotten by net.getCellInfo().

Return Value:

An array [mnc, ……, mnc] containing mnc of cells. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution

-1 - Failed execution

For EC600N/EC600E/EC800E/EC200A/EC600M/EC800M/BG95 series module, the value needs to be converted to hexadecimal. For example, Decimal number 1120 is 0x460 in hexadecimal in which 460 indicates MCC460. For other series modules, this value is in decimal format.

Example:

>>> import net
>>> net.getMcc()
[1120, 0]

net.getServingMcc

net.getServingMcc()

This method gets MCC of the serving cell. The result gotten by this interface is the collection of MCCs in the result gotten by net.getCellInfo().

Return Value:

mcc of the serving cell - Successful execution

-1 - Failed execution

For EC600N/EC600E/EC800E/EC200A/EC600M/EC800M/BG95 series module, the value needs to be converted to hexadecimal. For example, Decimal number 1120 is 0x460 in hexadecimal in which 460 indicates MCC460. For other series modules, this value is in decimal format.

Example:

>>> import net
>>> net.getServingMcc()
1120

Get LAC of Cell

net.getLac

net.getLac()

This method gets LACs of the neighbour cells. The result gotten by this interface is the collection of LACs in the result gotten by net.getCellInfo().

Return Value:

An array [lac, ……, lac] containing lac of cells. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution

-1 - Failed execution

Example:

>>> import net
>>> net.getLac()
[21771, 0]

net.getServingLac

net.getServingLac()

This method gets LACs of the serving cells. The result gotten by this interface is the collection of LACs in the result gotten by net.getCellInfo().

Return Value:

lac of the serving cell - Successful execution

-1 - Failed execution

Example:

>>> import net
>>> net.getServingLac()
56848

Work Mode Configuration

net.getModemFun

net.getModemFun()

This method gets the current work mode.

Return Value:

The current work mode of the module - Successful execution

-1 - Failed execution

Mode Description
0 Minimum functionality. In this mode, the entire radio frequency network protocol stack is completely closed, and the power supply to the SIM card is stopped.
1 Full functionality (default). In this mode, the device can send and receive RF signals.
4 Disable UE from both transmitting and receiving RF signals.

The BC32 series does not support mode 4.

Example:

>>> import net
>>> net.getModemFun()
1

net.setModemFun

net.setModemFun(fun [, rst])

This method sets the current work mode of the module.

Parameter:

  • fun - Integer type. Work mode of the module.
Mode Description
0 Minimum functionality. In this mode, the entire radio frequency network protocol stack is completely closed, and the power supply to the SIM card is stopped.
1 Full functionality (default). In this mode, the device can send and receive RF signals.
4 Disable UE from both transmitting and receiving RF signals.
  • rst - Integer type. Reboot flag. Optional parameter.
Value Description
0 Do not reboot the module after setting the current work mode (default).
1 Reboot the module after setting the current work mode.

Return Value:

0 - Successful execution

-1 - Failed execution

Example:

>>> import net
>>> net.setModemFun(4)
0

Set and Get Band

net.setBand

net.setBand(netRat, gsmBand, bandTuple)

This method sets the required band, that is, lock the band specified by the user if the module supports this method.

  • Comparison Table of Band Values
Network Mode Band Value
EGPRS(GSM) EGSM900 - 0x1
DCS1800 - 0x2
GSM850 - 0x4
PCS1900 - 0x8
LTE/eMTC/NB-IoT BAND1 - 0x1
BAND2 - 0x2
BAND3 - 0x4
BAND4 - 0x8
BAND5 - 0x10
BAND7 - 0x40
BAND8 - 0x80
BAND12 - 0x800
BAND13 - 0x1000
BAND18 - 0x20000
BAND19 - 0x40000
BAND20 - 0x80000
BAND25 - 0x1000000
BAND26 - 0x2000000
BAND27 - 0x4000000
BAND28 - 0x8000000
BAND31 - 0x40000000
BAND66 - 0x20000000000000000
BAND71 - 0x400000000000000000
BAND72 - 0x800000000000000000
BAND73 - 0x1000000000000000000
BAND85 - 0x1000000000000000000000
  • Supported band of BG95-M3 Series Module
Network Mode Supported Band
eMTC B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B26/B27/B28/B66/B85
NB-IoT B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B28/B66/B71/B85
EGPRS GSM850/EGSM900/DCS1800/PCS1900
  • Supported band of EG912N-ENAA Series Module
Network Mode Supported Band
LTE B1/B3/B5/B7/B8/B20/B28/B31/B72
EGPRS EGSM900/DCS1800

Parameter:

  • netRat - Integer type. Network mode. It indicates the kind of network mode whose band is to be set.
RAT Value Description
0 GSM network
1 LTE network
2 Cat M network
3 NB-IoT network
  • gsmBand - Integer type. The band value of GSM network. See the band value comparison table above.

  • bandtuple - The band value of other network modes excluding GSM network and it is a tuple containing 4 elements (band_hh, band_hl, band_lh, band_ll), each of which cannot exceed 4 bytes.

    band_hh - The first 4 bytes of the first 8 bytes of the band value.
    band_hl - The last 4 bytes of the first 8 bytes of the band value.
    band_lh - The first 4 bytes of the last 8 bytes of the band value.
    band_ll - The last 4 bytes of the last 8 bytes of the band value.
    If you want to set the band value to the band_value :
    band_hh = (band_value & 0xFFFFFFFF000000000000000000000000) >> 96
    band_hl = (band_value & 0x00000000FFFFFFFF0000000000000000) >> 64
    band_lh = (band_value & 0x0000000000000000FFFFFFFF00000000) >> 32
    band_ll = (band_value & 0x000000000000000000000000FFFFFFFF)

Return Value:

0 - Successful execution

-1 - Failed execution

  • Currently, BG95 series module/EG912N-ENAA module supports this method.
  • BG95 series module does not support the band of LTE network.
  • EG912N-ENAA module only supports the band of GSM network and LTE network.

Example:

import net
import utime

'''
You can directly use the following two interfaces to set and get the band. 
'''
def set_band(net_rat, band_value):
    if net_rat == 0:
        retval = net.setBand(0, band_value, (0, 0, 0, 0))
    else:
        band_hh = (band_value & 0xFFFFFFFF000000000000000000000000) >> 96
        band_hl = (band_value & 0x00000000FFFFFFFF0000000000000000) >> 64
        band_lh = (band_value & 0x0000000000000000FFFFFFFF00000000) >> 32
        band_ll = (band_value & 0x000000000000000000000000FFFFFFFF)
        retval = net.setBand(net_rat, 0, (band_hh, band_hl, band_lh, band_ll))
    return retval


def get_band(net_rat):
    return net.getBand(net_rat)

#======================================================================================================

'''
Sets the band of GSM network to 0xa, that is,  DCS1800 + PCS1900
0xa = 0x2(DCS1800) + 0x8(PCS1900)
'''
def set_gsm_band_example():
    print('Set GSM band to 0xa example:')
    gsm_band = get_band(0)
    print('GSM band value before setting:{}'.format(gsm_band))
    ret = set_band(0, 0xa)
    if ret == 0:
        print('Set GSM band successfully.')
    else:
        print('Set GSM band failed.')
    utime.sleep(1) # It takes time to set the band. You can wait for a period of time before getting new results.
    gsm_band = get_band(0)
    print('GSM band value after setting:{}'.format(gsm_band))
    return ret


'''
Sets the band of eMTC network to 0x15, that is BAND1 + BAND3 + BAND5
0x15 = 0x1(BAND1) + 0x4(BAND3) + 0x10(BAND5)
'''
def set_camt_band_example():
    print('Set CATM band to 0x15 example:')
    catm_band = get_band(2)
    print('CATM band value before setting:{}'.format(catm_band))
    ret = set_band(2, 0x15)
    if ret == 0:
        print('Set CATM band successfully.')
    else:
        print('Set CATM band failed.')
    utime.sleep(1) # It takes time to set the band. You can wait for a period of time before getting new results.
    catm_band = get_band(2)
    print('CATM band value after setting:{}'.format(catm_band))
    return ret


'''
Sets the band of NB-IoT network to 0x1000800000000000020011, that is BAND1 + BAND5 + BAND18 + BAND71 + BAND85   
0x1000400000000000020011 = 0x1 + 0x10 + 0x20000 + 0x400000000000000000 + 0x1000000000000000000000
'''
def set_nb_band_example():
    print('Set NB band to 0x1000400000000000020011 example:')
    nb_band = get_band(3)
    print('NB band value before setting:{}'.format(nb_band))
    ret = set_band(3, 0x1000400000000000020011)
    if ret == 0:
        print('Set NB band successfully.')
    else:
        print('Set NB band failed.')
    utime.sleep(1) # It takes time to set the band. You can wait for a period of time before getting new results.
    nb_band = get_band(3)
    print('NB band value after setting:{}'.format(nb_band))
    return ret


def main():
    set_gsm_band_example()
    utime.sleep(1)
    set_camt_band_example()
    utime.sleep(1)
    set_nb_band_example()


if __name__ == '__main__':
    main()


#===================================================================================================
# Running results
Set GSM band to 0xa example:
GSM band value before setting:0xf
Set GSM band successfully.
GSM band value after setting:0xa

Set CATM band to 0x15 example:
CATM band value before setting:0x10000200000000090e189f
Set CATM band successfully.
CATM band value after setting:0x15

Set NB band to 0x1000400000000000020011 example:
NB band value before setting:0x10004200000000090e189f
Set NB band successfully.
NB band value after setting:0x1000400000000000020011

net.getBand

net.getBand(netRat)

This method gets the band value in the current network mode.

Parameter:

  • netRat - Integer type. Network mode. It indicates that the band of which network mode you want to set.
RAT Value Description
0 GSM network
1 LTE network
2 Cat M network
3 NB-IoT network

Return Value:

Band value in hexadecimal.

  • Currently, BG95 series module/EG912N-ENAA module supports this method.
  • BG95 series module does not support the band of LTE network.
  • EG912N-ENAA module only supports the band of GSM network and LTE network.

Example:

>>> import net
>>> net.getBand(2)
'0x10000200000000090e189f'  # The band is in string type. If you need the value in integer type, int(data) can be called for changing the type.

net.bandRst

net.bandRst()

This method restores the initial set value of the band.

Return Value:

0 - Successful execution

-1 - Failed execution

Note: EG912N-ENAA series module supports this method.

Example:

'''
Sets to other bands first, calls this interface and checks whether it is successfully restored to the initial value.    
Initial set value of EG912N-ENAA series module: gsm_band:0x3(EGSM900/DCS1800 )  lte_band:0x8000000000480800D5(B1/B3/B5/B7/B8/B20/B28/B31/B72 )
'''
>>> import net
>>> net.bandRst()
0